MCP servercom.ardenvaleconstruction/tools
Planning tools for commercial and industrial construction.
Overview
Score?
UNRATED 0.143
of what a free look can see, on 1 looks
Looks
1
last 1 day ago
Tools
9
More info
URL
ardenvaleconstruction.com/mcp
streamable-http
Says it is
Ardenvale Construction 1.0.0
protocol 2025-06-18
In the record since
1 day ago
Among servers32,723 with a card
0median 0.547 · this server 0.143 · highest on record 0.8351
Toolsfrom sha256:7098198ed3…964132
| Tool | Schema |
|---|---|
| accessible_washroom_clearance_checker Pass or fail check of barrier-free stall, ambulatory stall or universal washroom clear dimensions against Ontario Building Code Articles 3.8.3.8 and 3.8.3.12. Preliminary clearance |
input · no output |
| child_care_space_checker Check indoor play space, outdoor play space and sleeping area per child for an Ontario licensed child care centre. Preliminary planning check only. Licensing is decided by the mini |
input · no output |
| exit_width_and_egress_door_calculator Required exit width, number of exits, door count and travel distance limit for an occupant load under Ontario Building Code Subsections 3.4.2 and 3.4.3. Preliminary planning figure |
input · no output |
| occupant_load_calculator Minimum design occupant load for a floor area from Ontario Building Code Table 3.1.17.1 area per person values. Preliminary planning figure only. The architect, the engineer and th |
input · no output |
| office_space_calculator Estimate usable and rentable office square feet from headcount, growth, desk sharing, rooms, circulation and load factor. Preliminary planning estimate only. The architect's test f |
input · no output |
| parking_stall_count_for_change_of_use Indicative parking stall count for a change of use in Toronto, Mississauga or Brampton from the zoning by-law rates, with the by-law named. Confirm with the municipality. Indicativ |
input · no output |
| restaurant_seating_and_washroom_requirement Occupant load, seat capacity and minimum patron and employee water closets and lavatories for an Ontario restaurant or bar (Building Code Table 3.7.4.3.-D, -E and -F). Preliminary |
input · no output |
| retail_store_layout_and_aisle_width_calculator Occupant load, exits, aisle widths and accessible route for an Ontario retail store, with a fixture run estimate from shelving depth. Preliminary planning figure only. The architec |
input · no output |
| washroom_fixture_calculator Minimum water closets and lavatories for each sex in an Ontario office or retail space (Building Code Tables 3.7.4.7 and 3.7.4.8). Preliminary planning figure only. Accessible and |
input · no output |
Verify it yourself