Server definition
- Hash
- sha256:7098198ed3566ca2cbe12e54f9bdc303034880a39b0cd6bbf63aba02a6964132
- What it is
- What a remote MCP server returned when asked what it offers: 9 tools
The blob, as servednamed by its sha256
{
"instructions": "Free planning calculators for Ontario commercial space. Every result is a preliminary planning figure. Tool page and free quote links are in each answer.",
"tools": [
{
"description": "Pass or fail check of barrier-free stall, ambulatory stall or universal washroom clear dimensions against Ontario Building Code Articles 3.8.3.8 and 3.8.3.12. Preliminary clearance check only. The architect, the accessibility consultant and the building official govern. This does not certify a washroom.",
"inputSchema": {
"properties": {
"change_table_space_length_mm": {
"description": "Universal washroom: clear space length for an adult change table. Unit: mm.",
"type": "number"
},
"change_table_space_width_mm": {
"description": "Universal washroom: clear space width for an adult change table. Unit: mm.",
"type": "number"
},
"door_clear_opening_mm": {
"description": "Door clear opening with the door open (all types). Unit: mm.",
"type": "number"
},
"door_swing": {
"description": "Stall door swing.",
"enum": [
"outward",
"inward"
],
"type": "string"
},
"front_clear_diameter_mm": {
"description": "Stall only: diameter of clear floor space in front of the stall. Unit: mm.",
"type": "number"
},
"inward_door_clear_area_ok": {
"description": "Stall with inward door: is a clear floor area of 820 mm by 1,440 mm inside the stall, clear of the door swing?",
"type": "boolean"
},
"latch_height_mm": {
"description": "Universal washroom: latch height above the floor. Unit: mm.",
"type": "number"
},
"lavatory_knee_clearance_mm": {
"description": "Clearance under the lavatory at the front edge. Unit: mm.",
"type": "number"
},
"lavatory_rim_height_mm": {
"description": "Lavatory rim height above the floor. Unit: mm.",
"type": "number"
},
"power_door_operator": {
"description": "Universal washroom: power door operator fitted.",
"type": "boolean"
},
"room_length_mm": {
"description": "Universal washroom internal length. Unit: mm.",
"type": "number"
},
"room_width_mm": {
"description": "Universal washroom internal width. Unit: mm.",
"type": "number"
},
"seat_height_mm": {
"description": "Stall only: water closet seat height above the floor. Unit: mm.",
"type": "number"
},
"stall_depth_mm": {
"description": "Stall clear depth (stall and ambulatory). Unit: mm.",
"type": "number"
},
"stall_face_to_door_mm": {
"description": "Stall with inward washroom door: clearance from stall face to that door. Unit: mm.",
"type": "number"
},
"stall_face_to_obstruction_mm": {
"description": "Stall only: clearance from stall face to any wall-mounted fixture or obstruction. Unit: mm.",
"type": "number"
},
"stall_width_mm": {
"description": "Stall clear width (stall and ambulatory). Unit: mm.",
"type": "number"
},
"transfer_space_depth_mm": {
"description": "Stall only: clear transfer space depth beside the water closet. Unit: mm.",
"type": "number"
},
"transfer_space_width_mm": {
"description": "Stall only: clear transfer space width beside the water closet. Unit: mm.",
"type": "number"
},
"turning_diameter_mm": {
"description": "Universal washroom: diameter of open turning space. Unit: mm.",
"type": "number"
},
"type": {
"default": "stall",
"description": "stall: barrier-free water closet stall. ambulatory: ambulatory stall. universal: universal washroom.",
"enum": [
"stall",
"ambulatory",
"universal"
],
"type": "string"
},
"wc_centre_to_wall_mm": {
"description": "Stall only: water closet centre line to the nearest side wall. Unit: mm.",
"type": "number"
}
},
"required": [],
"type": "object"
},
"name": "accessible_washroom_clearance_checker",
"outputSchema": null
},
{
"description": "Check indoor play space, outdoor play space and sleeping area per child for an Ontario licensed child care centre. Preliminary planning check only. Licensing is decided by the ministry. The architect, the engineer and the permit set govern the design.",
"inputSchema": {
"properties": {
"groups": {
"description": "Required. Licensed age groups as group:children:floor_area, comma separated, for example preschool:24:70,infant:10:25.",
"type": "string"
},
"outdoor_area": {
"default": 0,
"description": "Outdoor play space available. 0 shows only the requirement. Unit: unit.",
"type": "number"
},
"six_hours": {
"default": true,
"description": "Program runs six hours or more in a day.",
"type": "boolean"
},
"sleeping_area": {
"default": 0,
"description": "Sleeping area available. Unit: unit.",
"type": "number"
},
"sleeping_children": {
"default": 0,
"description": "Children sleeping at one time. Unit: children.",
"type": "integer"
},
"unit": {
"default": "m2",
"description": "Area unit for every area value.",
"enum": [
"m2",
"ft2"
],
"type": "string"
}
},
"required": [
"groups"
],
"type": "object"
},
"name": "child_care_space_checker",
"outputSchema": null
},
{
"description": "Required exit width, number of exits, door count and travel distance limit for an occupant load under Ontario Building Code Subsections 3.4.2 and 3.4.3. Preliminary planning figure only. The architect, the fire protection engineer and the permit set govern the means of egress.",
"inputSchema": {
"properties": {
"door_clear_width_mm": {
"default": 850,
"description": "Clear opening of one door leaf you plan to use, 850 mm or more. Unit: mm.",
"type": "number"
},
"element": {
"default": "doorway",
"description": "Exit element to size in the headline answer.",
"enum": [
"doorway",
"corridor",
"ramp",
"ramp-steep",
"stair",
"stair-other"
],
"type": "string"
},
"floor_area_m2": {
"description": "Floor area, to test the one-exit option. Unit: m2.",
"type": "number"
},
"group": {
"default": "mercantile",
"description": "Major occupancy of the floor area.",
"enum": [
"assembly",
"residential",
"business",
"mercantile",
"industrial-low",
"industrial-medium",
"industrial-high",
"care"
],
"type": "string"
},
"max_diagonal_m": {
"description": "Maximum diagonal dimension of the floor area, to find the least distance between two exits. Unit: m.",
"type": "number"
},
"occupant_load": {
"description": "Occupant load of the floor area served (required). Use the occupant load calculator for the table value. Unit: persons.",
"type": "integer"
},
"sprinklered": {
"default": false,
"description": "Floor area sprinklered throughout.",
"type": "boolean"
},
"stairs_storeys_served": {
"default": 2,
"description": "Storeys the exit stair serves above the lowest exit level. Over 2 sets the 1,100 mm minimum stair width. Unit: storeys.",
"type": "integer"
},
"storeys": {
"default": 1,
"description": "Building height in storeys. Unit: storeys.",
"type": "integer"
},
"travel_distance_m": {
"description": "Longest travel distance from any point to an exit, measured along the path of travel. Unit: m.",
"type": "number"
}
},
"required": [
"occupant_load"
],
"type": "object"
},
"name": "exit_width_and_egress_door_calculator",
"outputSchema": null
},
{
"description": "Minimum design occupant load for a floor area from Ontario Building Code Table 3.1.17.1 area per person values. Preliminary planning figure only. The architect, the engineer and the permit set govern the occupant load used for design and approval.",
"inputSchema": {
"properties": {
"area": {
"description": "Floor area for each use (required). Comma separated when several uses are given. Unit: unit.",
"type": "number"
},
"unit": {
"default": "m2",
"description": "Area unit.",
"enum": [
"m2",
"ft2"
],
"type": "string"
},
"use": {
"description": "Use of the floor area (required). One slug, or several separated by commas to match area.",
"type": "string"
}
},
"required": [
"use",
"area"
],
"type": "object"
},
"name": "occupant_load_calculator",
"outputSchema": null
},
{
"description": "Estimate usable and rentable office square feet from headcount, growth, desk sharing, rooms, circulation and load factor. Preliminary planning estimate only. The architect's test fit, the building drawings and the permit set govern the actual layout.",
"inputSchema": {
"properties": {
"area_large_meeting_sqft": {
"default": 350,
"description": "Area per large meeting room. Unit: sq ft each.",
"type": "number"
},
"area_medium_meeting_sqft": {
"default": 200,
"description": "Area per medium meeting room. Unit: sq ft each.",
"type": "number"
},
"area_private_office_sqft": {
"default": 150,
"description": "Area per private office. Unit: sq ft each.",
"type": "number"
},
"area_reception_sqft": {
"default": 200,
"description": "Reception area. Unit: sq ft.",
"type": "number"
},
"area_small_meeting_sqft": {
"default": 110,
"description": "Area per small meeting room. Unit: sq ft each.",
"type": "number"
},
"area_storage_sqft": {
"default": 120,
"description": "Storage or server room area. Unit: sq ft.",
"type": "number"
},
"area_workstation_sqft": {
"default": 45,
"description": "Area per workstation. Unit: sq ft each.",
"type": "number"
},
"circulation_pct": {
"default": 25,
"description": "Circulation allowance added to the components. Unit: percent.",
"type": "number"
},
"employees": {
"description": "Employees now (required). Unit: people.",
"type": "integer"
},
"growth_pct": {
"default": 20,
"description": "Expected growth over the lease term. Unit: percent.",
"type": "number"
},
"kitchen_sqft": {
"default": 300,
"description": "Kitchen and break area. 0 for none. Unit: sq ft.",
"type": "number"
},
"large_meeting_rooms": {
"default": 1,
"description": "Large meeting rooms (12 or more people). Unit: count.",
"type": "integer"
},
"load_factor_pct": {
"default": 15,
"description": "Load factor: rentable = usable x (1 + load factor). Unit: percent.",
"type": "number"
},
"medium_meeting_rooms": {
"default": 1,
"description": "Medium meeting rooms (up to 8 people). Unit: count.",
"type": "integer"
},
"pattern": {
"default": "hybrid",
"description": "Work pattern. Sets the default desk sharing ratio.",
"enum": [
"office",
"hybrid",
"remote"
],
"type": "string"
},
"people_per_desk": {
"description": "Desk sharing ratio, 1 or more. Default follows pattern: office 1, hybrid 1.5, remote 3. Unit: people per desk.",
"type": "number"
},
"private_offices": {
"default": 4,
"description": "Private offices. Unit: count.",
"type": "integer"
},
"reception": {
"default": true,
"description": "Include a reception area.",
"type": "boolean"
},
"small_meeting_rooms": {
"default": 2,
"description": "Small meeting rooms (up to 4 people). Unit: count.",
"type": "integer"
},
"storage_room": {
"default": true,
"description": "Include a storage or server room.",
"type": "boolean"
}
},
"required": [
"employees"
],
"type": "object"
},
"name": "office_space_calculator",
"outputSchema": null
},
{
"description": "Indicative parking stall count for a change of use in Toronto, Mississauga or Brampton from the zoning by-law rates, with the by-law named. Confirm with the municipality. Indicative only. Parking requirements differ by municipality, zone and site-specific exceptions. Confirm with the municipality's zoning examiner.",
"inputSchema": {
"properties": {
"brampton_core": {
"default": false,
"description": "Brampton only: the property is inside the Downtown, Central Area and Hurontario/Main Corridor area (Schedule B-7), which has no minimum.",
"type": "boolean"
},
"city": {
"description": "Municipality (required). Only cities whose by-law we opened are offered.",
"enum": [
"toronto",
"mississauga",
"brampton"
],
"type": "string"
},
"gross_floor_area_m2": {
"description": "Gross floor area of the use (required). Each by-law defines its own gross floor area. Unit: m2.",
"type": "number"
},
"use": {
"description": "Proposed use (required). Not every use is mapped for every city.",
"type": "string"
},
"zone": {
"default": "other",
"description": "Toronto: parking zone pza, pzb or other. Mississauga: parking precinct 1, 2, 3 or 4. Ignored for Brampton.",
"enum": [
"pza",
"pzb",
"other",
"1",
"2",
"3",
"4"
],
"type": "string"
}
},
"required": [
"city",
"use",
"gross_floor_area_m2"
],
"type": "object"
},
"name": "parking_stall_count_for_change_of_use",
"outputSchema": null
},
{
"description": "Occupant load, seat capacity and minimum patron and employee water closets and lavatories for an Ontario restaurant or bar (Building Code Table 3.7.4.3.-D, -E and -F). Preliminary planning figure only. The architect, the public health unit, the building official and the permit set govern the seat count and the fixture count.",
"inputSchema": {
"properties": {
"dining_area_m2": {
"description": "Dining, beverage and cafeteria floor area open to patrons (required). Unit: m2.",
"type": "number"
},
"employees": {
"default": 8,
"description": "Employees normally present at one time, those present more than 25 percent of the working day (Sentence 3.7.4.3.(9)). Unit: people.",
"type": "integer"
},
"male_pct": {
"default": 50,
"description": "Share counted as male, 0 to 100. The rest are counted as female. Unit: percent.",
"type": "number"
},
"seats": {
"default": 0,
"description": "Seats planned. 0 to use the occupant load from the area. The occupant load is the larger of the two. Unit: seats.",
"type": "integer"
},
"service": {
"default": "restaurant",
"description": "restaurant: a dining room or cafeteria (Table 3.7.4.3.-D). bar: an establishment used primarily for alcoholic beverages with limited or no food service (Table 3.7.4.3.-E).",
"enum": [
"restaurant",
"bar"
],
"type": "string"
},
"storeys": {
"default": 1,
"description": "Storeys in the building (sets the minimum number of universal washrooms). Unit: storeys.",
"type": "integer"
},
"urinals": {
"default": true,
"description": "Use urinals for males up to the Code limit.",
"type": "boolean"
}
},
"required": [
"dining_area_m2"
],
"type": "object"
},
"name": "restaurant_seating_and_washroom_requirement",
"outputSchema": null
},
{
"description": "Occupant load, exits, aisle widths and accessible route for an Ontario retail store, with a fixture run estimate from shelving depth. Preliminary planning figure only. The architect, the fire protection engineer and the permit set govern the layout and the means of egress.",
"inputSchema": {
"properties": {
"aisle_width_mm": {
"default": 1100,
"description": "Clear aisle width you plan between fixtures. Unit: mm.",
"type": "number"
},
"door_clear_width_mm": {
"default": 850,
"description": "Clear opening of one door leaf, 850 mm or more. Unit: mm.",
"type": "number"
},
"fixture_depth_mm": {
"default": 600,
"description": "Depth of one fixture run (for example a double-sided gondola). Unit: mm.",
"type": "number"
},
"floor_area_m2": {
"description": "Retail floor area on the storey (required). Unit: m2.",
"type": "number"
},
"sprinklered": {
"default": false,
"description": "Floor area sprinklered throughout.",
"type": "boolean"
},
"store_width_m": {
"description": "Store width, to estimate the number of fixture runs. Depth is area divided by width. Unit: m.",
"type": "number"
},
"storey": {
"default": "first",
"description": "Storey type, which sets the area per person: first (basement or first storey, 3.70 m2), upper-entrance (second storey with principal entrance from a pedestrian thoroughfare or parking area, 3.70 m2), other (5.60 m2).",
"enum": [
"first",
"upper-entrance",
"other"
],
"type": "string"
},
"storeys": {
"default": 1,
"description": "Building height in storeys. Unit: storeys.",
"type": "integer"
},
"travel_distance_m": {
"description": "Longest travel distance from any point to an exit. Unit: m.",
"type": "number"
}
},
"required": [
"floor_area_m2"
],
"type": "object"
},
"name": "retail_store_layout_and_aisle_width_calculator",
"outputSchema": null
},
{
"description": "Minimum water closets and lavatories for each sex in an Ontario office or retail space (Building Code Tables 3.7.4.7 and 3.7.4.8). Preliminary planning figure only. Accessible and universal washroom rules apply separately. The architect, the engineer and the permit set govern.",
"inputSchema": {
"properties": {
"area_m2": {
"default": 400,
"description": "Retail only: total area excluding basements. Unit: m2.",
"type": "number"
},
"male_pct": {
"default": 50,
"description": "Share counted as male, 0 to 100. The rest are counted as female. Unit: percent.",
"type": "number"
},
"persons": {
"description": "Occupant load (office) or employees at one time (retail). Required. Unit: people.",
"type": "integer"
},
"public": {
"default": 80,
"description": "Retail only: customers at one time. Unit: people.",
"type": "integer"
},
"type": {
"default": "office",
"description": "Occupancy: office (Group D, Table 3.7.4.7) or retail (Group E, Table 3.7.4.8).",
"enum": [
"office",
"retail"
],
"type": "string"
},
"urinals": {
"default": true,
"description": "Use urinals for males up to the Code limit.",
"type": "boolean"
}
},
"required": [
"persons"
],
"type": "object"
},
"name": "washroom_fixture_calculator",
"outputSchema": null
}
]
}Verify it yourself
curl -s https://api.teppi.xyz/v1/evidence/sha256:7098198ed3566ca2cbe12e54f9bdc303034880a39b0cd6bbf63aba02a6964132 | sha256sum