The blob, as servednamed by its sha256
{
"instructions": "Free renovation tools for Toronto and Ontario homeowners from Andare Homes. Each tool returns the answer, its source and a link to the tool page and the free quote form. Preliminary planning only.",
"tools": [
{
"description": "Ramp length for a rise at the Ontario Building Code 1 in 12 gradient, a slope check, or a doorway clear width check, using Section 3.8. Preliminary planning only. Example: /api/tools/accessible-ramp-and-doorway-calculator?mode=len&units=mm&rise=600",
"inputSchema": {
"properties": {
"door": {
"description": "Which doorway (mode door): path = barrier-free path of travel; suite-wide = bathroom or bedroom door in a suite served by a corridor 1,060 mm or wider; suite-narrow = same, corridor narrower than 1,060 mm",
"enum": [
"path",
"suite-wide",
"suite-narrow"
],
"type": "string"
},
"mode": {
"description": "len = ramp length needed for a rise (needs rise); slope = check an existing slope (needs rise and run); door = doorway clear width (needs width and door)",
"enum": [
"len",
"slope",
"door"
],
"type": "string"
},
"rise": {
"description": "Total rise (modes len and slope) (units)",
"type": "number"
},
"run": {
"description": "Horizontal run (mode slope) (units)",
"type": "number"
},
"units": {
"description": "Units of rise, run and width",
"enum": [
"mm",
"in"
],
"type": "string"
},
"width": {
"description": "Clear width with the door open (mode door) (units)",
"type": "number"
}
},
"required": [
"mode"
],
"type": "object"
},
"name": "accessible-ramp-and-doorway-calculator",
"outputSchema": null
},
{
"description": "Tests basement ceiling height, height under beams and ducts, and stair headroom against Ontario Building Code Part 9, for a house basement or a secondary suite. Window sizes are tested by the egress window size calculator. Preliminary planning only. Example: /api/tools/basement-ceiling-height-and-egress-checker?units=mm&type=suite&ceiling=2000&obstruction=1900&stair=1980",
"inputSchema": {
"properties": {
"bedroom": {
"description": "house only: a bedroom is planned in the basement",
"enum": [
"yes",
"no"
],
"type": "string"
},
"bedroom_low": {
"description": "house with bedroom only: lowest ceiling in the bedroom (units)",
"type": "number"
},
"bedroom_share": {
"description": "house with bedroom only: percent of the required bedroom floor area with a ceiling of 2,300 mm or more (%)",
"type": "number"
},
"ceiling": {
"description": "Finished ceiling height over the main part of the space, floor to underside of the finished ceiling (units)",
"type": "number"
},
"obstruction": {
"description": "Lowest clear height under a beam or duct (units)",
"type": "number"
},
"share": {
"description": "house only: percent of the basement floor area with a ceiling of 2,100 mm or more (default 100 when the ceiling is 2,100 mm or more, otherwise 0) (%)",
"type": "number"
},
"stair": {
"description": "Clear height over the basement stair, measured from the line through the tread nosings (units)",
"type": "number"
},
"type": {
"description": "house = basement of a house without a secondary suite; suite = secondary suite",
"enum": [
"house",
"suite"
],
"type": "string"
},
"units": {
"description": "Units of every height",
"enum": [
"mm",
"in"
],
"type": "string"
}
},
"required": [
"type",
"ceiling"
],
"type": "object"
},
"name": "basement-ceiling-height-and-egress-checker",
"outputSchema": null
},
{
"description": "Minimum bathroom exhaust fan rating in CFM from room size, ceiling height and fixtures, using the Home Ventilating Institute guidance. Preliminary planning only. Example: /api/tools/bathroom-exhaust-fan-calculator?units=ft&length=8&width=10&height=8",
"inputSchema": {
"properties": {
"fixtures": {
"description": "Comma separated fixtures in the room; needed only when the room is over 100 sq ft",
"type": "string"
},
"height": {
"description": "Ceiling height (units)",
"type": "number"
},
"length": {
"description": "Room length (units)",
"type": "number"
},
"units": {
"description": "Units of length, width and height",
"enum": [
"ft",
"m"
],
"type": "string"
},
"width": {
"description": "Room width (units)",
"type": "number"
}
},
"required": [
"length",
"width"
],
"type": "object"
},
"name": "bathroom-exhaust-fan-calculator",
"outputSchema": null
},
{
"description": "Says whether a deck in Toronto needs a building permit, whether a guard is required, the minimum guard height, opening size and stair handrail rule, from the City of Toronto and Ontario Building Code Part 9. Preliminary planning only. Example: /api/tools/deck-permit-and-guard-checker-toronto?units=mm&height=900&attached=yes&roofed=no&exit=no&risers=4&guard_height=900&gap=90",
"inputSchema": {
"properties": {
"attached": {
"description": "The deck is attached to the house",
"enum": [
"yes",
"no"
],
"type": "string"
},
"exit": {
"description": "The deck forms part of an exit required under the Building Code",
"enum": [
"yes",
"no",
"unsure"
],
"type": "string"
},
"gap": {
"description": "Planned clear opening between pickets or balusters (units)",
"type": "number"
},
"guard_height": {
"description": "Planned guard height (units)",
"type": "number"
},
"height": {
"description": "Height of the finished deck surface above the adjacent finished grade (units)",
"type": "number"
},
"risers": {
"description": "Number of risers on the deck stairs (whole number)",
"type": "number"
},
"roofed": {
"description": "The deck has a roof",
"enum": [
"yes",
"no"
],
"type": "string"
},
"units": {
"description": "Units of height, guard height and gap",
"enum": [
"mm",
"in"
],
"type": "string"
}
},
"required": [
"height",
"attached",
"roofed",
"exit"
],
"type": "object"
},
"name": "deck-permit-and-guard-checker-toronto",
"outputSchema": null
},
{
"description": "Tests a bedroom escape window against Ontario Building Code Article 9.9.10.1: open area of at least 0.35 m2, no dimension under 380 mm, sill height and window well clearance. Preliminary planning only. Example: /api/tools/egress-window-size-calculator?units=mm&type=casement&width=600&height=700&floor=basement&well=yes&well_clearance=600",
"inputSchema": {
"properties": {
"floor": {
"description": "basement = window in a basement area; above = any other floor",
"enum": [
"basement",
"above"
],
"type": "string"
},
"height": {
"description": "Clear height of the unobstructed open portion with the window fully open (units)",
"type": "number"
},
"sill": {
"description": "Sill height above the floor (tested only when floor is above) (units)",
"type": "number"
},
"type": {
"description": "Window type",
"enum": [
"casement",
"awning",
"single-hung",
"double-hung",
"sliding",
"hopper",
"other"
],
"type": "string"
},
"units": {
"description": "Units of width, height, sill and clearance",
"enum": [
"mm",
"in"
],
"type": "string"
},
"well": {
"description": "The window opens into a window well",
"enum": [
"yes",
"no"
],
"type": "string"
},
"well_clearance": {
"description": "Clearance in front of the window inside the well (units)",
"type": "number"
},
"width": {
"description": "Clear width of the unobstructed open portion with the window fully open (units)",
"type": "number"
}
},
"required": [
"type",
"width",
"height",
"floor"
],
"type": "object"
},
"name": "egress-window-size-calculator",
"outputSchema": null
},
{
"description": "Checks height, separation, floor area, setbacks and lot coverage of a garden suite against Toronto By-law 849-2025. Preliminary planning only. Example: /api/tools/garden-suite-zoning-checker?zone=yes&laneway=no&lot_area=400&lot_depth=40&lot_frontage=10&house_gfa=180&house_footprint=90&ancillary_footprint=40&suite_height=4&separation=5&suite_gfa=50&rear_setback=2&side_setback=1.5&one_storey=yes&rear_openings=no&side_openings=yes",
"inputSchema": {
"properties": {
"ancillary_footprint": {
"description": "Footprint of all ancillary buildings together, including the suite (m2)",
"type": "number"
},
"house_footprint": {
"description": "House footprint (m2)",
"type": "number"
},
"house_gfa": {
"description": "House gross floor area, all floors (m2)",
"type": "number"
},
"laneway": {
"description": "Property abuts a public laneway",
"enum": [
"yes",
"no"
],
"type": "string"
},
"lot_area": {
"description": "Lot area (m2)",
"type": "number"
},
"lot_depth": {
"description": "Lot depth (m)",
"type": "number"
},
"lot_frontage": {
"description": "Lot frontage (m)",
"type": "number"
},
"one_storey": {
"description": "Suite is one storey",
"enum": [
"yes",
"no"
],
"type": "string"
},
"rear_openings": {
"description": "Rear lot line abuts a residential-zone lot and the rear wall has openings more than 4.0 m above grade",
"enum": [
"yes",
"no"
],
"type": "string"
},
"rear_setback": {
"description": "Rear yard setback (m)",
"type": "number"
},
"separation": {
"description": "Distance from the main wall of the house (m)",
"type": "number"
},
"side_openings": {
"description": "Side wall facing a side lot line (not a street) has doors or windows",
"enum": [
"yes",
"no"
],
"type": "string"
},
"side_setback": {
"description": "Smallest side yard setback (m)",
"type": "number"
},
"suite_gfa": {
"description": "Suite gross floor area, all floors including a basement (m2)",
"type": "number"
},
"suite_height": {
"description": "Suite height from average grade (m)",
"type": "number"
},
"zone": {
"description": "Property is in a residential zone (R, RD, RS, RT, RM)",
"enum": [
"yes",
"no",
"unsure"
],
"type": "string"
}
},
"required": [
"zone",
"laneway",
"lot_area",
"lot_depth",
"lot_frontage",
"house_gfa",
"house_footprint",
"ancillary_footprint",
"suite_height",
"separation",
"suite_gfa",
"rear_setback",
"side_setback",
"one_storey",
"rear_openings",
"side_openings"
],
"type": "object"
},
"name": "garden-suite-zoning-checker",
"outputSchema": null
},
{
"description": "How much paint, how many drywall sheets or how many boxes of flooring a rectangular room needs, with an adjustable waste allowance. Quantities only. Preliminary planning only. Example: /api/tools/renovation-materials-calculator?material=paint&units=ft&length=12&width=10&height=8&openings=40&coats=2&coverage=350",
"inputSchema": {
"properties": {
"box_coverage": {
"description": "Coverage printed on one box of flooring (floor) (sq ft or m2)",
"type": "number"
},
"ceiling": {
"description": "Include the ceiling (paint and drywall)",
"enum": [
"yes",
"no"
],
"type": "string"
},
"coats": {
"description": "Number of coats (paint)",
"type": "number"
},
"coverage": {
"description": "Coverage printed on the paint can (paint) (sq ft per gallon or m2 per litre)",
"type": "number"
},
"height": {
"description": "Ceiling height (paint and drywall) (units)",
"type": "number"
},
"length": {
"description": "Room length (units)",
"type": "number"
},
"material": {
"description": "What to calculate",
"enum": [
"paint",
"drywall",
"floor"
],
"type": "string"
},
"openings": {
"description": "Doors and windows to subtract (paint and drywall) (area in sq ft or m2)",
"type": "number"
},
"sheet": {
"description": "Drywall sheet length in feet, 4 ft wide (drywall)",
"enum": [
"8",
"10",
"12"
],
"type": "string"
},
"units": {
"description": "ft = feet, sq ft and gallons; m = metres, m2 and litres",
"enum": [
"ft",
"m"
],
"type": "string"
},
"waste": {
"description": "Waste allowance in percent (drywall and floor) (%)",
"type": "number"
},
"width": {
"description": "Room width (units)",
"type": "number"
}
},
"required": [
"material",
"length",
"width"
],
"type": "object"
},
"name": "renovation-materials-calculator",
"outputSchema": null
},
{
"description": "A checklist of Ontario Building Code, Planning Act, Fire Code and City of Toronto items to check before adding a secondary suite to a house, each with its section number. Preliminary planning only. Example: /api/tools/second-suite-requirements-checklist?building=detached&smaller=yes&units_now=1&location=basement&fuel=yes&parking=one&rental=yes",
"inputSchema": {
"properties": {
"building": {
"description": "Existing building type",
"enum": [
"detached",
"semi",
"row",
"other"
],
"type": "string"
},
"fuel": {
"description": "A fuel-burning appliance, flue, fireplace or attached garage is in or next to the suite",
"enum": [
"yes",
"no",
"unsure"
],
"type": "string"
},
"location": {
"description": "Where the suite will be",
"enum": [
"basement",
"above",
"addition"
],
"type": "string"
},
"parking": {
"description": "Parking spaces available for the suite",
"enum": [
"none",
"one",
"more"
],
"type": "string"
},
"rental": {
"description": "The suite will be rented",
"enum": [
"yes",
"no",
"unsure"
],
"type": "string"
},
"smaller": {
"description": "The new unit will be smaller than the main unit",
"enum": [
"yes",
"no"
],
"type": "string"
},
"units_now": {
"description": "Dwelling units in the house now",
"enum": [
"1",
"2"
],
"type": "string"
}
},
"required": [
"building",
"smaller",
"units_now",
"location",
"fuel",
"parking",
"rental"
],
"type": "object"
},
"name": "second-suite-requirements-checklist",
"outputSchema": null
},
{
"description": "Gives the number of risers allowed for a total rise, the rise and run of each option, and tests headroom and width against Ontario Building Code Part 9 Section 9.8. Preliminary planning only. Example: /api/tools/stair-calculator-ontario?units=mm&type=private&rise=2600&run=3500&headroom=1980&width=900",
"inputSchema": {
"properties": {
"headroom": {
"description": "Clear height over the stair (units)",
"type": "number"
},
"rise": {
"description": "Total rise from finished floor to finished floor (units)",
"type": "number"
},
"run": {
"description": "Total horizontal run available (units)",
"type": "number"
},
"type": {
"description": "private = stairs inside or outside a house or dwelling unit; public = public stairs in a residential building",
"enum": [
"private",
"public"
],
"type": "string"
},
"units": {
"description": "Units of rise, run, headroom and width",
"enum": [
"mm",
"in"
],
"type": "string"
},
"width": {
"description": "Stair width (units)",
"type": "number"
}
},
"required": [
"rise"
],
"type": "object"
},
"name": "stair-calculator-ontario",
"outputSchema": null
},
{
"description": "Says whether a project in Toronto needs a building permit, usually does not, or depends, with the City source for the answer. Preliminary planning only. Example: /api/tools/toronto-building-permit-checker?project=deck&h=high&att=yes&exit=no",
"inputSchema": {
"properties": {
"att": {
"description": "deck: Will the deck be attached to the house? | shed: Will it be attached to a house, garage or any other structure?",
"enum": [
"yes",
"no"
],
"type": "string"
},
"bt": {
"description": "opening: What kind of building is it?",
"enum": [
"house",
"other"
],
"type": "string"
},
"chg": {
"description": "opening: Will the work affect the structural support or create a new exit?",
"enum": [
"yes",
"no",
"unsure"
],
"type": "string"
},
"exit": {
"description": "deck: Will it have a roof, or will it be part of a required exit from the house?",
"enum": [
"yes",
"no",
"unsure"
],
"type": "string"
},
"h": {
"description": "deck: How high will the finished deck level be above the adjacent finished grade?",
"enum": [
"low",
"high",
"unsure"
],
"type": "string"
},
"ht": {
"description": "fence: How tall will it be?",
"enum": [
"t12",
"t20",
"over"
],
"type": "string"
},
"kind": {
"description": "opening: What is the work? | plumbing: What is the plumbing work?",
"enum": [
"new",
"repl",
"add",
"valve"
],
"type": "string"
},
"lb": {
"description": "wall: Is the wall load bearing?",
"enum": [
"yes",
"no",
"unsure"
],
"type": "string"
},
"mech": {
"description": "basement: Will it include new plumbing or heating work?",
"enum": [
"yes",
"no"
],
"type": "string"
},
"plumb": {
"description": "kitchen: Will you add or move plumbing, such as relocating a sink, shower, tub, toilet or drain? | shed: Will it have plumbing?",
"enum": [
"yes",
"no"
],
"type": "string"
},
"pool": {
"description": "fence: Is the fence a swimming pool enclosure?",
"enum": [
"yes",
"no"
],
"type": "string"
},
"project": {
"description": "What is being built",
"enum": [
"basement",
"deck",
"wall",
"opening",
"kitchen",
"plumbing",
"shed",
"roofing",
"fence"
],
"type": "string"
},
"scope": {
"description": "kitchen: Is the work limited to replacing cabinets, counters, finishes and fixtures in the same locations?",
"enum": [
"yes",
"no"
],
"type": "string"
},
"size": {
"description": "shed: What is the gross floor area?",
"enum": [
"small",
"exact",
"big"
],
"type": "string"
},
"struct": {
"description": "basement: Will it include structural or material alterations, such as adding or removing walls, excavation, underpinning or a new basement entrance? | roofing: Will the work include any structural repair, such as replacing rafters, trusses or framing, or changing the roof shape?",
"enum": [
"yes",
"no",
"unsure"
],
"type": "string"
},
"suite": {
"description": "basement: Will the work create a second suite or any additional dwelling unit?",
"enum": [
"yes",
"no"
],
"type": "string"
},
"walls": {
"description": "kitchen: Will you add or remove any walls or change any openings?",
"enum": [
"yes",
"no"
],
"type": "string"
},
"where": {
"description": "fence: Where will the fence be?",
"enum": [
"front",
"other"
],
"type": "string"
}
},
"required": [
"project"
],
"type": "object"
},
"name": "toronto-building-permit-checker",
"outputSchema": null
},
{
"description": "Gives the last day of the City of Toronto published review time for a complete building permit application, by review stream. Preliminary planning only. Example: /api/tools/toronto-permit-review-time-calculator?stream=house&date=2026-12-01&zoning_certificate=yes",
"inputSchema": {
"properties": {
"date": {
"description": "Date the complete application is taken in (YYYY-MM-DD)",
"type": "string"
},
"stream": {
"description": "Review stream: house = House Stream (10 business days); small = Small Building Stream (15); large = Large and Complex, large building (20); complex = Large and Complex, complex building (30); express = Express Services (goal of 3)",
"enum": [
"house",
"small",
"large",
"complex",
"express"
],
"type": "string"
},
"zoning_certificate": {
"description": "Application includes an issued Zoning Applicable Law Certificate and all fees paid",
"enum": [
"yes",
"no"
],
"type": "string"
}
},
"required": [
"stream",
"date",
"zoning_certificate"
],
"type": "object"
},
"name": "toronto-permit-review-time-calculator",
"outputSchema": null
}
]
}Verify it yourself