Server definition
- Hash
- sha256:d7b1874950a06b90da3e4825793bcebe869d53992c3b05ee075ee0b151b928a4
- What it is
- What a remote MCP server returned when asked what it offers: 3 tools
The blob, as servednamed by its sha256
{
"instructions": "Use CordFind tools for generator cord and connector research. Treat every result as planning guidance, preserve safety notices, and direct users to the supplied CordFind verification URL.",
"tools": [
{
"description": "Compare common American Wire Gauge sizes using load current, voltage, one-way distance, and a voltage-drop planning limit.",
"inputSchema": {
"$schema": "https://json-schema.org/draft/2020-12/schema",
"properties": {
"amps": {
"anyOf": [
{
"const": 15,
"type": "number"
},
{
"const": 20,
"type": "number"
},
{
"const": 30,
"type": "number"
},
{
"const": 50,
"type": "number"
}
],
"description": "Planned current in amperes"
},
"distanceFeet": {
"description": "One-way cord distance in feet",
"maximum": 200,
"minimum": 10,
"type": "number"
},
"dropLimitPercent": {
"anyOf": [
{
"const": 3,
"type": "number"
},
{
"const": 5,
"type": "number"
}
],
"default": 3,
"description": "Planning voltage-drop limit"
},
"volts": {
"anyOf": [
{
"const": 120,
"type": "number"
},
{
"const": 240,
"type": "number"
}
],
"description": "Circuit voltage"
}
},
"required": [
"amps",
"volts",
"distanceFeet"
],
"type": "object"
},
"name": "calculate_generator_cord_size",
"outputSchema": null
},
{
"description": "Screen a generator outlet, destination, and cord distance for direct compatibility, adapter needs, verification boundaries, or unsafe paths.",
"inputSchema": {
"$schema": "https://json-schema.org/draft/2020-12/schema",
"properties": {
"distanceFeet": {
"anyOf": [
{
"const": 25,
"type": "number"
},
{
"const": 50,
"type": "number"
},
{
"const": 100,
"type": "number"
}
],
"description": "Planned cord distance in feet"
},
"sourceConnectorId": {
"description": "Generator receptacle family",
"enum": [
"520",
"1450",
"l1430",
"l1420",
"l630",
"l530",
"cs50",
"tt30"
],
"type": "string"
},
"targetId": {
"description": "Intended destination",
"enum": [
"inlet",
"rv",
"appliance",
"distribution"
],
"type": "string"
}
},
"required": [
"sourceConnectorId",
"targetId",
"distanceFeet"
],
"type": "object"
},
"name": "get_connector_compatibility",
"outputSchema": null
},
{
"description": "Search CordFind for generator cords, plugs, sizing, transfer equipment, maintenance, and safety guidance.",
"inputSchema": {
"$schema": "https://json-schema.org/draft/2020-12/schema",
"properties": {
"limit": {
"default": 5,
"description": "Maximum results",
"maximum": 10,
"minimum": 1,
"type": "integer"
},
"query": {
"description": "Generator topic or question",
"maxLength": 100,
"minLength": 2,
"type": "string"
}
},
"required": [
"query"
],
"type": "object"
},
"name": "search_generator_guides",
"outputSchema": null
}
]
}Verify it yourself