Endpoints: 28,729MCP servers: 18,413Payout addresses: 2,071Paid calls: 1,536Letters: 14Defects: 1,322counted just now
teppi

Server definition

Hash
sha256:8f50ba4ceead39b4bc7e1e2cb1941c4ee1543b6c4ae2a3725a81904437561f81
What it is
What a remote MCP server returned when asked what it offers: 27 tools

The blob, as servednamed by its sha256

{ "instructions": null, "tools": [ { "description": "Assess EU EPBD (2024) compliance. Returns compliance score, renovation cost estimate, deadline pressure, and priority retrofit measures.", "inputSchema": { "properties": { "building_type": { "description": "e.g. office, residential, retail, school, hospital", "type": "string" }, "country": { "description": "e.g. germany, france, netherlands, ireland, uk", "type": "string" }, "current_epc": { "enum": [ "A", "B", "C", "D", "E", "F", "G" ], "type": "string" }, "floor_area_m2": { "type": "number" }, "has_solar_pv": { "type": "boolean" }, "heating_system": { "description": "gas_boiler, heat_pump, district_heating, electric, oil_boiler, biomass", "type": "string" }, "year_built": { "type": "integer" } }, "required": [ "building_type", "year_built", "current_epc", "heating_system", "has_solar_pv", "floor_area_m2", "country" ], "type": "object" }, "name": "assess_epbd_score", "outputSchema": null }, { "description": "Building carbon footprint (Scope 1/2/3) with CRREM stranding check and embodied carbon. Returns per-scope tCO2e, intensity, CRREM compliance, net-zero gap and priority actions.", "inputSchema": { "properties": { "building_type": { "enum": [ "office", "retail", "industrial", "datacentre", "healthcare", "education", "residential" ], "type": "string" }, "elec_kwh_year": { "type": "number" }, "floor_area_m2": { "type": "number" }, "gas_kwh_year": { "type": "number" }, "heat_kwh_year": { "type": "number" }, "location": { "enum": [ "uk", "eu", "uae" ], "type": "string" }, "occupancy": { "type": "number" }, "refrigerant": { "enum": [ "hfc", "hfo", "none" ], "type": "string" }, "renewable_pct": { "type": "number" }, "year_built": { "type": "integer" } }, "required": [ "building_type", "floor_area_m2", "location", "year_built" ], "type": "object" }, "name": "building_carbon_footprint", "outputSchema": null }, { "description": "Building Readiness assessment for change-of-use / conversion. Returns a 0-100 readiness score, project complexity, four domain scores (structural, MEP, compliance, digital/BIM) with RAG, and recommendations.", "inputSchema": { "properties": { "bim": { "enum": [ "yes", "partial", "no" ], "type": "string" }, "condition": { "enum": [ "good", "fair", "poor", "unknown" ], "type": "string" }, "current_use": { "enum": [ "office", "industrial", "retail", "residential" ], "type": "string" }, "floors": { "enum": [ "1-3", "4-6", "7-10", "10+" ], "type": "string" }, "location": { "enum": [ "uk", "western-eu", "eastern-eu", "uae" ], "type": "string" }, "proposed_use": { "enum": [ "office", "residential", "healthcare", "industrial", "retail" ], "type": "string" }, "structure": { "enum": [ "concrete", "steel", "masonry", "timber", "unknown" ], "type": "string" }, "year_built": { "enum": [ "pre1945", "1945-1970", "1970-1990", "1990-2010", "post2010" ], "type": "string" } }, "required": [ "current_use", "proposed_use", "year_built", "structure", "floors", "condition", "location", "bim" ], "type": "object" }, "name": "building_readiness", "outputSchema": null }, { "description": "Calculate operational + embodied carbon and net-zero gap (CIBSE TM65 / RICS WLCA). Returns carbon intensity, benchmark, and prioritised reduction measures with payback.", "inputSchema": { "properties": { "building_type": { "description": "office, residential, retail, industrial, hospital, warehouse, hotel", "type": "string" }, "construction_year": { "type": "integer" }, "country": { "description": "ISO-2: gb, de, fr, nl, es, pl, ro, it, ae, us", "type": "string" }, "energy_kwh_year": { "description": "Measured annual energy; 0 to use benchmark", "type": "number" }, "floor_area_m2": { "type": "number" } }, "required": [ "floor_area_m2", "building_type", "country" ], "type": "object" }, "name": "calculate_carbon", "outputSchema": null }, { "description": "Calculate Power Usage Effectiveness (PUE) for a data centre or server room. Returns PUE score, efficiency rating, annual cost estimate, and engineering recommendations.", "inputSchema": { "properties": { "cooling_kw": { "description": "Total cooling system power in kW. Example: 200", "type": "number" }, "it_load_kw": { "description": "IT equipment power draw in kW. Example: 500", "type": "number" }, "lighting_kw": { "description": "Lighting power in kW. Example: 1.5", "type": "number" }, "ups_losses_kw": { "description": "UPS and power distribution losses in kW. Example: 25", "type": "number" } }, "required": [ "it_load_kw", "cooling_kw", "ups_losses_kw", "lighting_kw" ], "type": "object" }, "name": "calculate_pue", "outputSchema": null }, { "description": "Assess UAE grid connection feasibility (DEWA/ADDC/SEWA/FEWA). Returns feasibility score, connection timeline, recommended voltage, substation requirement, and next steps.", "inputSchema": { "properties": { "has_existing_supply": { "type": "boolean" }, "intended_use": { "enum": [ "data_centre", "commercial", "industrial", "mixed" ], "type": "string" }, "power_requirement_mw": { "type": "number" }, "site_location": { "enum": [ "dubai", "abu_dhabi", "sharjah", "ajman", "other" ], "type": "string" }, "target_completion_year": { "type": "integer" }, "voltage_level": { "enum": [ "LV", "MV", "HV" ], "type": "string" } }, "required": [ "site_location", "power_requirement_mw", "voltage_level", "intended_use", "has_existing_supply", "target_completion_year" ], "type": "object" }, "name": "check_grid_feasibility_uae", "outputSchema": null }, { "description": "Assess NIS2 Directive (EU 2022/2555) compliance readiness. Returns compliance score (0-18), maturity level, estimated fine exposure, and prioritised remediation actions.", "inputSchema": { "properties": { "has_24h_reporting": { "type": "boolean" }, "has_asset_inventory": { "type": "boolean" }, "has_board_reporting": { "type": "boolean" }, "has_ciso": { "type": "boolean" }, "has_ir_plan": { "type": "boolean" }, "has_network_segmentation": { "type": "boolean" }, "has_ot_monitoring": { "type": "boolean" }, "has_ot_policy": { "type": "boolean" }, "has_supplier_assessment": { "type": "boolean" }, "organisation_size": { "enum": [ "essential", "important", "other" ], "type": "string" }, "sector": { "description": "e.g. energy, transport, healthcare, banking", "type": "string" } }, "required": [ "has_ciso", "has_ot_policy", "has_board_reporting", "has_asset_inventory", "has_network_segmentation", "has_ir_plan", "has_24h_reporting", "has_supplier_assessment", "has_ot_monitoring", "organisation_size", "sector" ], "type": "object" }, "name": "check_nis2_readiness", "outputSchema": null }, { "description": "Check UAE BIM mandate applicability (Dubai Circular 196, Abu Dhabi DMT, Sharjah). Returns mandate status, compliance score, required LOD, and submission checklist.", "inputSchema": { "properties": { "bim_software": { "description": "e.g. Revit 2024", "type": "string" }, "building_area_m2": { "type": "number" }, "building_floors": { "type": "integer" }, "building_type": { "enum": [ "residential", "commercial", "healthcare", "government", "mixed" ], "type": "string" }, "emirate": { "enum": [ "dubai", "abu_dhabi", "sharjah", "other" ], "type": "string" }, "has_bep": { "type": "boolean" }, "has_bim_model": { "type": "boolean" }, "ifc_export": { "type": "boolean" } }, "required": [ "building_area_m2", "building_floors", "emirate", "building_type", "has_bim_model", "bim_software", "ifc_export", "has_bep" ], "type": "object" }, "name": "check_uae_bim_compliance", "outputSchema": null }, { "description": "Assess UAE cybersecurity regulatory compliance (NESA IAS, Dubai ISR, CBUAE, TDRA). Returns applicable framework, compliance score, critical gaps, and mandatory controls.", "inputSchema": { "properties": { "emirate": { "description": "dubai, abu_dhabi, sharjah, federal, other", "type": "string" }, "has_data_classification": { "type": "boolean" }, "has_incident_response": { "type": "boolean" }, "has_isms": { "type": "boolean" }, "has_third_party_audit": { "type": "boolean" }, "has_vulnerability_assessment": { "type": "boolean" }, "is_cloud_hosted": { "type": "boolean" }, "organisation_type": { "enum": [ "government", "critical_infrastructure", "financial", "telecom", "other" ], "type": "string" } }, "required": [ "organisation_type", "emirate", "has_isms", "has_incident_response", "has_vulnerability_assessment", "has_third_party_audit", "has_data_classification", "is_cloud_hosted" ], "type": "object" }, "name": "check_uae_cybersecurity", "outputSchema": null }, { "description": "NIS2 / EPBD contractor vetting score from a 12-question checklist across financial, technical, cyber (NIS2) and energy (EPBD) categories. Flags blocking (critical) failures and returns recommended additional checks. Not a formal due-diligence report.", "inputSchema": { "properties": { "answers": { "description": "Map of question_id -> yes|no|unknown. IDs: registered, insurance, no_prosecutions, certifications, references, cvs, cyber_policy, incident_reporting, access_control, assessor_cert, energy_qual, reno_experience", "type": "object" }, "purpose": { "description": "Vetting purpose", "enum": [ "nis2", "epbd", "general", "critical" ], "type": "string" } }, "required": [ "answers" ], "type": "object" }, "name": "contractor_vetting", "outputSchema": null }, { "description": "DGNB certification pre-score and BIM (ISO 19650) maturity self-assessment from a 20-question checklist. Returns pre-score, achievable certification level, BIM level, domain breakdown and prioritised gaps. Not a formal DGNB audit.", "inputSchema": { "properties": { "answers": { "description": "Map of question_id -> yes|partial|no. IDs: lca, materials, water, biodiversity, lcc, flexibility, value_stability, cert_budget, comfort, accessibility, wellbeing, satisfaction, bep, cde, competency, clash, integrated_team, commissioning, documentation, poe", "type": "object" }, "cert_target": { "description": "Target DGNB level", "enum": [ "bronze", "silver", "gold", "platinum" ], "type": "string" } }, "required": [ "answers" ], "type": "object" }, "name": "dgnb_bim_readiness", "outputSchema": null }, { "description": "EPBD-style staged digital renovation passport: 3-phase roadmap (quick wins, system upgrades, deep renovation) with cost ranges, energy savings and EPC trajectory from current EPC, floor area and heating type. Indicative.", "inputSchema": { "properties": { "address": { "description": "Building address (label only)", "type": "string" }, "building_type": { "description": "Building type (label only)", "type": "string" }, "country": { "description": "Country code (e.g. UK, DE)", "type": "string" }, "current_epc": { "description": "Current EPC band A-G", "enum": [ "A", "B", "C", "D", "E", "F", "G" ], "type": "string" }, "era": { "description": "Construction era (label only)", "type": "string" }, "floor_area_m2": { "description": "Gross floor area (m2)", "type": "number" }, "heating": { "description": "Primary heating system", "enum": [ "gas", "oil", "hp", "district", "electric", "biomass" ], "type": "string" } }, "required": [ "floor_area_m2", "current_epc", "heating" ], "type": "object" }, "name": "digital_renovation_passport", "outputSchema": null }, { "description": "EU Energy Efficiency Directive data-centre reporting pack (Dir (EU) 2023/1791 Art.12 + Del. Reg (EU) 2024/1364). Determines reporting scope (IT power >= 500 kW) and computes the mandated KPIs PUE, WUE, ERF and REF. Note: the regulation mandates reporting, not target values.", "inputSchema": { "properties": { "it_energy_kwh": { "description": "EIT: IT energy (kWh/yr)", "type": "number" }, "it_power_kw": { "description": "Installed IT power demand (kW)", "type": "number" }, "renewable_energy_kwh": { "description": "ERES-TOT renewable energy consumed, for REF", "type": "number" }, "reused_heat_kwh": { "description": "EREUSE waste heat reused, for ERF", "type": "number" }, "total_energy_kwh": { "description": "EDC: total data-centre energy (kWh/yr)", "type": "number" }, "water_input_m3": { "description": "WIN: total water input (m3/yr), for WUE", "type": "number" } }, "required": [ "it_power_kw", "total_energy_kwh", "it_energy_kwh" ], "type": "object" }, "name": "eed_datacentre_pack", "outputSchema": null }, { "description": "Estimate cooling load using CIBSE Guide B2 / ASHRAE methodology. Returns required capacity, installed capacity with redundancy, system recommendation, and annual energy.", "inputSchema": { "properties": { "climate_zone": { "enum": [ "northern_eu", "central_eu", "southern_eu", "uk", "uae_gcc" ], "type": "string" }, "floor_area_m2": { "type": "number" }, "it_load_kw": { "description": "Required for data_centre/server_room. Set 0 for others.", "type": "number" }, "occupancy_persons": { "type": "integer" }, "redundancy": { "enum": [ "N", "N+1", "2N" ], "type": "string" }, "space_type": { "enum": [ "office", "data_centre", "server_room", "retail", "industrial" ], "type": "string" } }, "required": [ "space_type", "floor_area_m2", "it_load_kw", "occupancy_persons", "climate_zone", "redundancy" ], "type": "object" }, "name": "estimate_cooling_load", "outputSchema": null }, { "description": "Parametric construction cost benchmark across UK/EU/GCC by country, project type, specification, procurement, programme and BIM. Returns per-m2 and total cost ranges plus a cost breakdown. Indicative parametric estimate, validate against current cost indices.", "inputSchema": { "properties": { "bim": { "enum": [ "yes", "no" ], "type": "string" }, "country": { "description": "Country", "enum": [ "UK", "DE", "FR", "NL", "ES", "PL", "RO", "BE", "AT", "UAE", "SA" ], "type": "string" }, "floor_area_m2": { "description": "Gross floor area (m2), min 100", "type": "number" }, "procurement": { "enum": [ "traditional", "db", "epc", "ppp" ], "type": "string" }, "programme": { "enum": [ "accelerated", "standard", "extended" ], "type": "string" }, "project_type": { "description": "Project type", "enum": [ "office_new", "resi_new", "data_centre", "industrial", "healthcare", "retail", "reno_light", "reno_deep", "infrastructure" ], "type": "string" }, "specification": { "enum": [ "basic", "standard", "premium", "ultra" ], "type": "string" } }, "required": [ "floor_area_m2", "country", "project_type" ], "type": "object" }, "name": "eu_cost_benchmarking", "outputSchema": null }, { "description": "Preliminary Eurocode beam design (steel EC3 / composite / reinforced concrete EC2). Selects a section, computes ULS bending & shear utilisation, SLS deflection, and fire protection. Indicative, not a stamped design.", "inputSchema": { "properties": { "config": { "description": "ss=simply supported, cant=cantilever, cont=continuous 2-span", "enum": [ "ss", "cant", "cont" ], "type": "string" }, "exposure": { "description": "Concrete exposure class (cover)", "enum": [ "xc1", "xc2", "xc3" ], "type": "string" }, "fire_rating": { "description": "Required fire rating", "enum": [ "r30", "r60", "r90", "r120" ], "type": "string" }, "grade": { "description": "Steel: s275/s355. Concrete: c2530/c3037/c3545", "type": "string" }, "load_position": { "description": "Point-load position as fraction of span 0-1 (default 0.5)", "type": "number" }, "material": { "description": "Beam material", "enum": [ "steel", "composite", "concrete" ], "type": "string" }, "point_load_kn": { "description": "Characteristic point load (kN), optional", "type": "number" }, "span_m": { "description": "Span length (m)", "type": "number" }, "udl_kn_m": { "description": "Characteristic uniformly distributed load (kN/m)", "type": "number" } }, "required": [ "material", "config", "span_m", "udl_kn_m" ], "type": "object" }, "name": "eurocode_beam_designer", "outputSchema": null }, { "description": "Eurocode axial column buckling check (steel EC3 6.3.1 flexural buckling / RC EC2 5.8 simplified). Returns Ncr, non-dimensional slenderness, reduction factor chi, NRd and utilisation. Indicative, not a stamped design.", "inputSchema": { "properties": { "axial_load_kn": { "description": "Design axial load NEd (kN)", "type": "number" }, "buckling_curve": { "description": "EC3 buckling curve (steel only)", "enum": [ "a", "b", "c", "d" ], "type": "string" }, "depth_mm": { "description": "RC column depth h (mm), concrete only", "type": "number" }, "eccentricity_mm": { "description": "Load eccentricity (mm), optional", "type": "number" }, "effective_length_m": { "description": "Effective (buckling) length Lcr (m)", "type": "number" }, "material": { "description": "Section material", "enum": [ "S275", "S355", "C25", "C30" ], "type": "string" }, "reinforcement_pct": { "description": "RC reinforcement ratio % (concrete only)", "type": "number" }, "section": { "description": "Steel section key, e.g. UC203x203x46 (steel only)", "type": "string" }, "width_mm": { "description": "RC column width b (mm), concrete only", "type": "number" } }, "required": [ "axial_load_kn", "effective_length_m", "material" ], "type": "object" }, "name": "eurocode_column_checker", "outputSchema": null }, { "description": "Generate an indicative Technical Due Diligence (TDD) fee estimate. Returns preliminary and full DD fee ranges (GBP), turnaround days, and contact CTA.", "inputSchema": { "properties": { "building_type": { "description": "office, data_centre, industrial, retail, residential, mixed_use, hotel, warehouse, healthcare", "type": "string" }, "disciplines": { "items": { "enum": [ "structural", "mep", "compliance", "energy", "nis2" ], "type": "string" }, "type": "array" }, "geography": { "enum": [ "uk", "eu", "uae", "gcc" ], "type": "string" }, "gross_area_m2": { "type": "number" }, "timeline_weeks": { "type": "integer" }, "transaction_type": { "enum": [ "acquisition", "disposal", "refinancing", "planning" ], "type": "string" } }, "required": [ "building_type", "gross_area_m2", "transaction_type", "disciplines", "geography", "timeline_weeks" ], "type": "object" }, "name": "get_technical_dd_quote", "outputSchema": null }, { "description": "Domestic whole-dwelling fabric + ventilation heat-loss estimate for heat pump sizing (BS EN 12831 / MCS), from floor area, storeys, age band, location and glazing. Returns design heat loss (kW), recommended heat pump output, indicative SCOP and annual demand. Typical U-values/SCOP, not measured.", "inputSchema": { "properties": { "age_band": { "enum": [ "pre_1900", "1900_1929", "1930_1949", "1950_1966", "1967_1975", "1976_1982", "1983_1990", "1991_1995", "1996_2002", "2003_2006", "2007_2011", "2012_2022", "2023_plus" ], "type": "string" }, "air_change_rate": { "description": "ACH, default 0.5", "type": "number" }, "ceiling_height_m": { "description": "Default 2.4", "type": "number" }, "external_design_temp_c": { "description": "Override 99.6% external design temp", "type": "number" }, "floor_area_m2": { "type": "number" }, "flow_temp_c": { "description": "Emitter flow temperature", "enum": [ 35, 45, 55 ], "type": "integer" }, "glazing_pct_of_floor": { "description": "Default 25", "type": "number" }, "internal_design_temp_c": { "description": "Default 21", "type": "number" }, "location": { "enum": [ "london", "birmingham", "manchester", "glasgow", "edinburgh", "leeds", "newcastle", "cardiff", "belfast", "plymouth", "southampton" ], "type": "string" }, "storeys": { "type": "integer" } }, "required": [ "floor_area_m2", "age_band", "location" ], "type": "object" }, "name": "heatpump_heatloss", "outputSchema": null }, { "description": "England & Wales Minimum Energy Efficiency Standard (MEES) check for private rented property. Tests against the in-force EPC E minimum (domestic and non-domestic) and surfaces the PROPOSED (not yet law) EPC C / 2030 uplift as an advisory only. Returns compliance, can-let, cost cap and penalties.", "inputSchema": { "properties": { "current_epc_band": { "enum": [ "A", "B", "C", "D", "E", "F", "G" ], "type": "string" }, "property_type": { "enum": [ "domestic", "non_domestic" ], "type": "string" } }, "required": [ "property_type", "current_epc_band" ], "type": "object" }, "name": "mees_checker", "outputSchema": null }, { "description": "UK Approved Document O 2021 simplified-method overheating check for new residential: tests maximum glazing area (by orientation, risk zone, cross vs single aspect) and minimum free ventilation area. Returns pass/fail and points to CIBSE TM59 modelling if it fails. Indicative.", "inputSchema": { "properties": { "cross_ventilation": { "enum": [ "yes", "no" ], "type": "string" }, "floor_area_m2": { "type": "number" }, "glazing_area_m2": { "type": "number" }, "location_risk": { "description": "high = listed London postcode districts (AD O Table C1)", "enum": [ "high", "moderate" ], "type": "string" }, "most_glazed_facade": { "enum": [ "N", "E", "S", "W" ], "type": "string" }, "provided_free_area_m2": { "description": "Total openable free area provided (optional)", "type": "number" } }, "required": [ "location_risk", "most_glazed_facade", "floor_area_m2", "glazing_area_m2" ], "type": "object" }, "name": "part_o_overheating", "outputSchema": null }, { "description": "UK Approved Document S 2021 electric-vehicle charge-point requirement calculator for new build and major renovation, residential and non-residential. Returns required charge points, cable routes (1-in-5 for non-residential), minimum power and the applicable cost caps/exemptions. Indicative.", "inputSchema": { "properties": { "building_type": { "enum": [ "residential", "non_residential" ], "type": "string" }, "covered_car_park": { "description": "Non-residential covered car park?", "enum": [ "yes", "no" ], "type": "string" }, "dwellings": { "description": "Number of dwellings (residential)", "type": "integer" }, "parking_spaces": { "description": "Total associated parking spaces", "type": "integer" }, "works": { "enum": [ "new", "major_renovation" ], "type": "string" } }, "required": [ "building_type", "works", "parking_spaces" ], "type": "object" }, "name": "part_s_ev", "outputSchema": null }, { "description": "Engineering ROI calculator. Returns current manual cost, annual saving, net benefit, ROI %, payback months, 3-year NPV and a verdict.", "inputSchema": { "properties": { "efficiency_gain_pct": { "description": "<=90", "type": "number" }, "hourly_rate": { "type": "number" }, "implementation_time_months": { "type": "number" }, "manual_hours": { "description": "manual hours per week", "type": "number" }, "software_cost": { "description": "annual GBP (default 0)", "type": "number" }, "team_size": { "type": "number" } }, "required": [ "team_size", "hourly_rate", "manual_hours", "efficiency_gain_pct", "implementation_time_months" ], "type": "object" }, "name": "roi_calculator", "outputSchema": null }, { "description": "UK SAP 10.3 / SBEM EPC precheck. Maps a known SAP rating (1-100) to its EPC band, and/or computes annual CO2 and primary energy from fuel consumption using validated SAP 10 fuel factors. The official EPC band is cost-based and needs a full SAP/RdSAP assessment.", "inputSchema": { "properties": { "annual_energy_kwh": { "description": "Map fuel -> kWh/yr. Fuels: mains_gas, grid_electricity, heating_oil, lpg, wood_pellets, wood_logs, wood_chips, biomass_community", "type": "object" }, "floor_area_m2": { "description": "For carbon/primary-energy intensity", "type": "number" }, "sap_rating": { "description": "Known SAP rating 1-100 (returns the EPC band)", "type": "number" } }, "required": [], "type": "object" }, "name": "sap_sbem_precheck", "outputSchema": null }, { "description": "Thermal Load Estimator for data centres / critical facilities. Returns total heat load, cooling capacity, units, airflow, chiller size, PUE estimate, power density, and a CRAC/CRAH/DLC/immersion comparison.", "inputSchema": { "properties": { "ambient_temp_c": { "type": "number" }, "cooling_type": { "enum": [ "crac", "crah", "dlc", "immersion" ], "type": "string" }, "it_load_kw": { "type": "number" }, "lighting_kw": { "description": "default 5", "type": "number" }, "redundancy": { "enum": [ "n", "n1", "2n" ], "type": "string" }, "room_area_m2": { "type": "number" }, "ups_efficiency_pct": { "description": "1-99.9", "type": "number" } }, "required": [ "it_load_kw", "ups_efficiency_pct", "room_area_m2", "cooling_type", "redundancy", "ambient_temp_c" ], "type": "object" }, "name": "thermal_load", "outputSchema": null }, { "description": "UAE Scope 1 + Scope 2 GHG estimate from electricity and gas use, with emirate-specific grid emission factors (Dubai/Abu Dhabi/national) and the Federal Decree-Law No. 11 of 2024 mandatory-reporting context. Grid factors carry base-year/confidence caveats.", "inputSchema": { "properties": { "electricity_kwh": { "description": "Annual grid electricity (kWh)", "type": "number" }, "emirate": { "enum": [ "dubai", "abu_dhabi", "national" ], "type": "string" }, "gas_kwh": { "description": "Annual natural gas (kWh)", "type": "number" }, "gas_m3": { "description": "Annual natural gas (m3), alternative to gas_kwh", "type": "number" } }, "required": [ "emirate", "electricity_kwh" ], "type": "object" }, "name": "uae_climate_ghg", "outputSchema": null }, { "description": "UK permitted-development (GPDO 2015, England) rules engine for extensions, loft conversions and change of use. Returns a verdict (likely_pd / requires_permission / complex), applicable PD class, conditions and flags (listed building, Article 4, conservation area, AONB). Indicative, verify with the LPA.", "inputSchema": { "properties": { "article_4": { "enum": [ "yes", "no", "unknown" ], "type": "string" }, "conservation_area": { "enum": [ "yes", "no" ], "type": "string" }, "extension_depth_m": { "description": "Rear extension depth (m), for extension proposals", "type": "number" }, "listed": { "enum": [ "yes", "no" ], "type": "string" }, "location": { "enum": [ "england", "wales", "scotland", "ni" ], "type": "string" }, "national_park_aonb": { "enum": [ "yes", "no" ], "type": "string" }, "property_type": { "enum": [ "house", "flat", "commercial", "industrial", "agricultural", "mixed" ], "type": "string" }, "proposal": { "enum": [ "extension", "loft", "outbuilding", "cou", "newdwelling", "subdivision", "demolition" ], "type": "string" }, "proposed_use": { "description": "Proposed use class (change of use only); 'same' if unchanged", "type": "string" }, "use_class": { "description": "Existing use class (C3, C1, E, B2, B8, F1, F2, SG)", "type": "string" } }, "required": [ "property_type", "proposal" ], "type": "object" }, "name": "uk_planning_checker", "outputSchema": null } ] }
Verify it yourselfcurl -s https://api.teppi.xyz/v1/evidence/sha256:8f50ba4ceead39b4bc7e1e2cb1941c4ee1543b6c4ae2a3725a81904437561f81 | sha256sum